211 / 309 page ![]() 8/01/00 Am79C976 211 P R E L I M INARY Table 90 indicates the possible combinations of EEDET and the existence of an EEPROM and the resulting operations that are pos- sible on the EEPROM interface. Table 90. EEDET Setting 12-5 RES Reserved locations. Written as zeros; read as undefined. 4 EEN EEPROM Port Enable. When this bit is set to a 1, it causes the val- ues of ECS, ESK, and EDI to be driven onto the EECS, EESK, and EEDI pins, respectively. If EEN = 0 and no EEPROM read function is currently active, then EECS will be driven LOW. When EEN = 0 and no EEPROM read function is currently active, EESK and EEDI pins will be driven by the LED registers BCR5 and BCR4, respectively. See Table 91. Read/Write accessible. EEN is set to 0 by H_RESET and is unaf- fected by S_RESET or STOP. 35($'DQG$XWR 5HDGUHTXLUHG DQ ((3520 ZLWKVXSSRUWIRUVHTXHQWLDO UHDG DXWRPDWLFDGGUHVV LQFUHPHQW 3 RES Reserved location. Written as zero and read as undefined. 2 ECS EEPROM Chip Select. This bit is used to control the value of the EECS pin of the interface when the EEN bit is set to 1 and the PREAD bit is set to 0. If EEN = 1 and PREAD = 0 and ECS is set to a 1, then the EECS pin will be forced to a HIGH level at the ris- ing edge of the next clock follow- ing bit programming. If EEN = 1 and PREAD = 0 and ECS is set to a 0, then the EECS pin will be forced to a LOW level at the rising edge of the next clock following bit programming. ECS has no effect on the output value of the EECS pin unless the PREAD bit is set to 0 and the EEN bit is set to 1. Read/Write accessible. ECS is set to 0 by H_RESET and is not affected by S_RESET or STOP. EEDET Value (BCR19[13]) EEPROM Connected? Result if PREAD is Set to 1 Result of Automatic EEPROM Read Operation Following H_RESET 0 No EEPROM read operation is attempted. Entire read sequence will occur; checksum failure will result; PVALID is reset to 0. First two EESK clock cycles are generated, then EEPROM read operation is aborted and PVALID is reset to 0. 0 Yes EEPROM read operation is attempted. Entire read sequence will occur; checksum operation will pass; PVALID is set to 1. First two EESK clock cycles are generated, then EEPROM read operation is aborted and PVALID is reset to 0. 1 No EEPROM read operation is attempted. Entire read sequence will occur; checksum failure will result; PVALID is reset to 0. EEPROM read operation is attempted. Entire read sequence will occur; checksum failure will result; PVALID is reset to 0. 1 Yes EEPROM read operation is attempted. Entire read sequence will occur; checksum operation will pass; PVALID is set to 1. EEPROM read operation is attempted. Entire read sequence will occur; checksum operation will pass; PVALID is set to 1. Table 91. Interface Pin Assignment 567 Pin *PREAD or Auto Read in Progress EEN EECS EESK EEDI Low X X 0 Tri-State Tri-State High 1 X Active Active Active High 0 1 From ECS Bit of BCR19 From ESK Bit of BCR19 From EEDI Bit of BCR19 High 0 0 0 LED1 LED0 |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |