| Electronic Components Datasheet Search |
|
PM5313 Datasheet(PDF) 328 Page - PMC-Sierra, Inc |
|
|
|||||||||||||||||||||||||||||
PM5313 Datasheet(HTML) 328 Page - PMC-Sierra, Inc |
|
328 / 646 page ![]() PRODUCTION PMC-Sierra, Inc. PM5313 SPECTRA-622 DATASHEET PMC-1981162 ISSUE 6 SONET/SDH PAYLOAD EXTRACTOR/ALIGNER FOR 622 MBIT/S PROPRIETARY AND CONFIDENTIAL 296 Register 011CH: SPECTRA-622 RPPS RALM Output Control #1 Bit Type Function Default Bit 7 R/W LOMRALM 0 Bit 6 R/W PRDIRALM 0 Bit 5 R/W PERDIRALM 0 Bit 4 R/W ALMRALM 0 Bit 3 R/W LOPRALM 0 Bit 2 R/W PAISRALM 0 Bit 1 R/W LOPCONRALM 0 Bit 0 R/W PAISCONRALM 0 This register along with SPECTRA-622 RALM Output Control #2 register controls the receive path alarm output (RALM) signal. These register bits should normally be set low when the RPPS is configured as a slave unless indicated otherwise. PAISCONRALM: The path alarm indication signal concatenation (PAISCON) RALM output enable bit allows the corresponding alarm to be ORed into the RALM output. When the enable bit is set high, the corresponding alarm indication is ORed with other alarm indications and output on RALM. When the enable bit is set low, the corresponding alarm indication does not affect the RALM output. NOTE: This register bit should only be used when the RPPS is configured as a slave. Otherwise, it should normally be set low. LOPCONRALM: The loss of pointer concatenation (LOPCON) RALM output enable bit allows the corresponding alarm to be ORed into the RALM output. When the enable bit is set high, the corresponding alarm indication is ORed with other alarm indications and output on RALM. When the enable bit is set low, the corresponding alarm indication does not affect the RALM output. NOTE: This register bit should only be used when the RPPS is configured as a slave. Otherwise, it should normally be set low. PAISRALM: The path alarm indication signal (PAIS) RALM output enable bit allows the corresponding alarm to be ORed into the RALM output. When the enable bit is set high, the corresponding alarm indication is ORed with other alarm indications and output on RALM. When the enable bit is set low, the corresponding alarm indication does not affect the RALM output. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |