| Electronic Components Datasheet Search |
|
ACS8530 Datasheet(PDF) 19 Page - Semtech Corporation |
|
|
|||||||||||||||||||||||||||||
ACS8530 Datasheet(HTML) 19 Page - Semtech Corporation |
|
19 / 152 page ![]() ADVANCED COMMUNICATIONS FINAL DATASHEET Revision 3.02/November 2005 © Semtech Corp. Page 19 www.semtech.com ACS8530 SETS Manual Mode (Reg. 34 Bit 4, cnfg_input_mode, man_holdover set High.) The Holdover frequency is determined by the value in register cnfg_holdover_frequency (Reg. 3E, Reg. 3F, and part of Reg. 40). This is a 19-bit signed number, with a LSB resolution of 0.0003068 ppm, which gives an adjustment range of ±80 ppm. This value can be derived from a reading of the register sts_current_DPLL_frequency (Reg. 0D, Reg. 0C and Reg. 07), which gives, in the same format, an indication of the current output frequency deviation, which would be read when the device is locked. If required, this value could be read by external software and averaged over time. The averaged value could then be fed to the cnfg_holdover_frequency register, ready for setting the averaged frequency value when the device enters Holdover mode. The sts_current_DPLL_frequency value is internally derived from the Digital Phase Locked Loop (DPLL) integral path, which represents a short-term average measure of the current frequency, depending on the locked loop bandwidth (Reg. 67) selected. It is also possible to combine the internal averaging filters with some additional software filtering. For example the internal fast filter could be used as an anti-aliasing filter and the software could further filter this before determining the actual Holdover frequency. To support this feature, a facility to read out the internally averaged frequency has been provided. By setting Reg. 40, Bit 5, cnfg_holdover_modes, read_average, the value read back from the cnfg_holdover_frequency register will be the filtered value. The filtered value is available regardless of what actual Holdover mode is selected. Clearly this results in the register not reading back the data that was written to it. Example: Software averaging to eliminate temperature drift. Select Manual Holdover mode by setting Reg. 34 Bit 4, cnfg_input_mode, man_holdover High. Select Fast Holdover Averaging mode by setting Reg. 40 Bit 6, cnfg_holdover_modes, auto_averaging High and Reg. 40 Bit 7 High. Select to be able to read back filtered output by setting Reg. 40 Bit 5, cnfg_holdover_modes, read_average High. Software periodically reads averaged value from the cnfg_holdover_frequency register and the temperature (not supplied from ACS8530). Software processes frequency and temperature and places data in software look-up table or other algorithm. Software writes back appropriate averaged value into the cnfg_holdover_frequency register. Once Holdover mode is entered, software periodically updates the cnfg_holdover_frequency register using the temperature information (not supplied from ACS8530). Mini-holdover Mode Holdover mode so far described refers to a state to which the internal state machine switches as a result of activity or frequency alarms, and this state is reported in Reg. 09. To avoid the DPLL’s frequency being pulled off as a result of a failed input, then the DPLL has a fast mechanism to freeze its current frequency within one or two cycles of the input clock source stopping. Under these circumstances the DPLL enters Mini-holdover mode; the Mini-holdover frequency used being determined by Reg. 40, Bits [4:3], cnfg_holdover_modes, mini_holdover_mode. Mini-holdover mode only lasts until one of the following happens: A new source has been selected, or The state machine enters Holdover mode, or The original fault on the input recovers. External Factors Affecting Holdover Mode If the external OCXO frequency is varying due to temperature fluctuations in the room, then the instantaneous value can be different from the average value, and then it may be possible to exceed the 0.05 ppm limit (depending on how extreme the temperature fluctuations are). It is advantageous to shield the OCXO to slow down frequency changes due to drift and external temperature fluctuations. The frequency accuracy of Holdover mode has to meet the ITU-T, ETSI and Telcordia performance requirements. The performance of the external oscillator clock is critical in this mode, although only the frequency stability is important - the stability of the output clock in Holdover is directly related to the stability of the external oscillator. Pre-locked2 Mode This state is very similar to the Pre-Locked state. It is entered from the Holdover state when a reference source has been selected and applied to the phase locked loop. It is also entered if the device is operating in Revertive mode and a higher-priority reference source is restored. The ACS8530 will spend a maximum of 100 seconds in the Pre-locked2 mode. If the device is required to spend |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |