| Electronic Components Datasheet Search |
|
ML7204-003 Datasheet(PDF) 53 Page - LAPIS Semiconductor Co., Ltd. |
|
|
|||||||||||||||||||||||||||||
ML7204-003 Datasheet(HTML) 53 Page - LAPIS Semiconductor Co., Ltd. |
|
53 / 214 page ![]() FEDL7204-003-02 ML7204-003 53/214 When receive data of the same channel is written in one frame or the receive data channel notification is invalid, an interrupt is generated by setting a receive side invalid write error flag (RXBW_ERR) to “1”. RXBW_ERR is retained from the next valid write period until immediately before the termination of the frame for which invalid receive data has no longer been written. Terminating 2-channel operation When returning a 2-channel operation mode to a single-channel operation mode, it is possible to notify which channel’s transmit/receive data is continuously encoded or decoded by setting an option in ACTCH_FLAG. To continue encoding/decoding of transmit/receive data of channel 1, set ACTCH_FLAG to “0” and then set SC_EN = 1 and DC_EN = 0. Encoding/decoding of channel 2 transmit/receive data stops within a maximum of 250 s; however, encoding/decoding of channel 1 transmit/receive data continues. To continue encoding/decoding of channel 2 transmit/receive data, set ACTCH_FLAG to “1” and then set SC_EN = 1 and DC_EN = 0. Encoding/decoding of channel 1 transmit/receive data stops within a maximum of 250 s; however, encoding/decoding of channel 2 transmit/receive data continues. Figure 32 shows an example where exchange of channel 1 transmit/receive data is continued. (Note) 1. In the frame where SC_EN = 1 and DC_EN = 0 are set, CH1/CH2 transmit data read requests and receive data write requests are issued normally. However, even if transmit data or receive data of the channel that was terminated is not read or written, an error does not occur. 2. After RXREQ_DC is cleared to “0”, write processing to RXFLAG_[CH2:CH1] is not necessary. 3. To set DC_EN = 1 again after setting DC_EN = 0, a wait period of approx. 10 ms or more is required after TXREQ_DC = 0 and RXREQ_DC = 0 are set. Performing single-channel operation Transmit Operates according to the contents described in Operation and Error processing in Figure 16. Note that FR0_CH1 is set to “1” when a transmit data read request is issued in this operation state or the CH1 transmit error flag (TXERR_CH1) is set to “1” at the occurrence of an error also in this operation state, even if continuation of encoding/decoding of channel 2 transmit/receive data is set in Terminating 2-channel operation. Receive Operates according to the contents described in Operation and Error processing in Figure 20. The G.711 PLC function enable control register (G711_PLCEN) is set to “0”. Note that the CH1 receive error flag (RXERR_CH1) is set to “1” at the occurrence of an error in this operation state even if continuation of encoding/decoding of the channel 2 transmit/receive data is set in Terminating 2-channel operation. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |