106 / 192 page ![]() PM8313 D3MX DATA SHEET PMC-920702 ISSUE 5 M13 MULTIPLEXER 96 Register 2AH: MX23 Mux AIS Insert Register Bit Type Function Default Bit7 Unused X Bit6 R/W MAIS[7] 0 Bit5 R/W MAIS[6] 0 Bit4 R/W MAIS[5] 0 Bit3 R/W MAIS[4] 0 Bit2 R/W MAIS[3] 0 Bit1 R/W MAIS[2] 0 Bit0 R/W MAIS[1] 0 MAIS[7:1]: Setting any of the MAIS[7:1] bits activates insertion of the alarm indication signal (all ones) into the corresponding DS2 stream multiplexed into the DS3 signal output on TDAT. Mux AIS insertion takes place before the point where per DS2 loopback may be invoked using the Loopback Activate register and thus mux AIS cannot be inserted while a DS2 loopback is activated. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|