29 / 71 page ![]() Data Sheet ADXL366 SERIAL COMMUNICATIONS analog.com Rev. 0 | 29 of 71 The ADXL366 communicates via a 4-wire SPI or I2C interface and operates as a subordinate. Ignore data that is transmitted from the ADXL366 to the main device during writes to the ADXL366. As shown in Figure 2 to Figure 7, the MISO pin is in a high impedance state (held by a bus keeper) except when the ADXL366 is sending read data, which is done to conserve bus power. Wire the ADXL366 for SPI communication, as shown in the connec- tion diagram in Figure 55. The recommended SPI clock speeds are 1MHz to 8MHz, with a 12pF maximum loading. The ADXL366 uses an SPI mode with a clock polarity (CPOL) of zero and a clock phase (CPHA) of zero. For correct operation of the device, the logic thresholds and timing parameters in Table 2 and Table 3 must be met at all times. Refer to Figure 10 and Figure 11 for visual diagrams of the timing parameters. Figure 55. 4-Wire SPI Connection Diagram SPI COMMANDS The SPI port uses a multibyte structure where the first byte is a command. The ADXL366 command set is as follows: ► 0x0A: write register ► 0x0B: read register ► 0x0D: read FIFO Read and Write Register Commands The command structure for the read register and write register commands is </CS down> <command byte (0x0A or 0x0B)> <ad- dress byte> <data byte> <additional data bytes for multi-byte> … </CS up>. The read and write register commands support multibyte (burst) read/write access. The waveform diagrams for multibyte read and write commands are shown in Figure 2 and Figure 3. Read FIFO Command Reading from the FIFO buffer is a command structure that does not have an address, </CS down> <command byte (0x0D)> <data byte> <data byte> … </CS up>. It is recommended that a full sample set be read (using a multibyte transaction). If a full sample set is not read using a multibyte transaction, FIFO can get discarded and the channel ID can slip out of synchronization. Data is presented most significant byte first, followed by the least significant byte. MULTIBYTE TRANSFERS Multibyte transfers, also known as burst transfers, are supported for all SPI commands (register read, register write, and FIFO read commands). It is recommended that data be read using multibyte transfers to ensure that a concurrent and complete set of x-axis, y-axis, and z-axis acceleration (and temperature, where applicable) data is read. The FIFO runs on the serial port clock during FIFO reads and can sustain bursting at the SPI clock rate as long as the SPI clock is fast enough to pop data faster than it is being written to the FIFO (depends on ODR). Register Read/Write Auto-Increment A register read or write command begins with the address specified in the command and auto-increments for each additional byte in the transfer. Register 0x00 to Register 0x45 are user accessible. A multibyte register read that extends past Register 0x45 gives valid data only up to Register 0x45. Any attempt to read a higher register may result in invalid data. INVALID ADDRESSES AND ADDRESS ALIASING The ADXL366 has a 7-bit address bus, mapping only 128 regis- ters in the possible 256 register address space. Register 0x00 to Register 0x45 are for customer access, as described in Table 11. Register 0x4E to Register 0x7F are reserved for factory use. Any attempt to read beyond Register 0x7F results in invalid data. LATENCY RESTRICTIONS Reading any of the data registers (Register 0x08 to Register 0x0A or Register 0x0E to Register 0x17) clears the data ready interrupt. There can be as much as a 120µs delay from reading a register to the clearing of the data ready interrupt. This delay can increase to 420μs in wake-up mode. Same delay applies to clear any other interrupt on STATUS, STATUS_COPY, and STATUS_2 registers. Other register reads, register writes, and FIFO reads have no latency restrictions. INVALID COMMANDS There are only three valid SPI commands for the ADXL366, 0x0A, 0x0B, and 0x0D. All other commands are invalid and must be avoided. When not receiving a valid command, the MISO output remains in a high impedance state, and the bus keeper holds the MISO line at its last value. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |