88 / 487 page ![]() LAN9354 DS00001926B-page 88 2015 Microchip Technology Inc. Note 1: LINKSTAT is the internal link status and is not directly available in any register bit. Note 2: WOL_INT is defined as bits 7:4 in the PHY x Wakeup Control and Status Register (PHY_WUCSR_x) ANDed with bits 3:0 of the same register, with the resultant 4 bits OR’ed together. Note 3: If the mask bit is enabled and the internal interrupt signal has been de-asserted while ENERGYON is still high, the internal interrupt signal will assert for 256 ms, approximately one second after ENERGYON goes low when the Cable is unplugged. To prevent an unexpected assertion of the internal interrupt signal, the ENERGYON interrupt mask should always be cleared as part of the ENERGYON interrupt service routine. 9.2.9.2 Alternate Interrupt Mode The Alternate interrupt mode is enabled by setting the ALTINT bit of the PHY x Mode Control/Status Register (PHY_- MODE_CONTROL_STATUS_x) to “1”. In this mode, to enable an interrupt, set the corresponding bit of the in the PHY x Interrupt Mask Register (PHY_INTERRUPT_MASK_x) (see Table 9-4). To clear an interrupt, clear the interrupt source and write a ‘1’ to the corresponding Interrupt Source Flag. Writing a ‘1’ to the Interrupt Source Flag will cause the state machine to check the Interrupt Source to determine if the Interrupt Source Flag should clear or stay as a ‘1’. If the con- 30.5 29.5 Remote Fault Detected 1.4 Remote Fault Rising 1.4 Falling 1.4, or Reading register 1 or Reading register 29 30.4 29.4 Link Down 1.2 Link Status Falling 1.2 Reading register 1 or Reading register 29 30.3 29.3 Auto-Negotia- tion LP Acknowl- edge 5.14 Acknowl- edge Rising 5.14 Falling 5.14 or Reading register 29 30.2 29.2 Parallel Detec- tion Fault 6.4 Parallel Detection Fault Rising 6.4 Falling 6.4 or Reading register 6, or Reading register 29, or Re-Auto Negotiate or Link down 30.1 29.1 Auto-Negotia- tion Page Received 6.1 Page Received Rising 6.1 Falling 6.1 or Reading register 6, or Reading register 29, or Re-Auto Negotiate, or Link down. Note: The Energy On (ENERGYON) bit in the PHY x Mode Control/Status Register (PHY_MODE_CON- TROL_STATUS_x) is defaulted to a ‘1’ at the start of the signal acquisition process, therefore the INT7 bit in the PHY x Interrupt Source Flags Register (PHY_INTERRUPT_SOURCE_x) will also read as a ‘1’ at power-up. If no signal is present, then both Energy On (ENERGYON) and INT7 will clear within a few mil- liseconds. TABLE 9-3: INTERRUPT MANAGEMENT TABLE (CONTINUED) |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |