27 / 264 page ![]() Chapter 2 AMD-761™ System Controller Programmer’s Interface 15 24081D—February 2002 AMD-761™ System Controller Software/BIOS Design Guide Preliminary Information 2.2.2 IACK In x86 compatible Socket2000 systems, APIC is used as the interrupt controller. To fetch the appropriate vector during IACK cycles, x86 processors are required to assert their APIC ID (CPU ID) on bits [15:12] of the address field when reading the IACK generation space. IACK return data flushes all PCI and AGP/PCI write buffers to memory. 2.2.3 PCI Configuration Accesses In legacy x86 PC systems, PCI configuration cycles are generated via an indirect method. A configuration address register is defined at I/O address 0CF8 that allows software to load a value that is asserted on the PCI address wires during the next configuration read/write cycle. A configuration data register is defined at I/O address 0CFC that allows software to generate configuration read and write cycles on the PCI using IN and OUT instructions. Data sent during OUT instructions to the Configuration Data register is asserted on the PCI data wires during the generated configuration write transaction. Data received in response to a generated configuration read transaction is returned to satisfy the IN from the Configuration Data register. In Socket2000 systems, PCI configuration cycles are generated in one of two ways: In EV6 Compatible mode, the x86 processor must detect IN and OUT instructions that reference 0CF8 and 0CFC and generate the appropriate, explicit RdBytes/Rd/LWs and WrBytes/WrLWs Socket2000 commands to a 16-Mbyte region as follows: • When an OUT instruction is detected to 0CF8, the write data is saved into a register and the instruction retired. • When an IN/OUT instruction is detected to 0CFC, an appropriate AMD Athlon system bus Rd/Wr transaction is launched with the SysAdd Field[23:0] taken from the register that saved the most recent write to 0CF8 (above). In traditional mode, which the AMD-761 system controller implements, IN and OUT instructions that reference 0CF8 and 0CFC are passed normally on to the AMD Athlon processor system bus where the Northbridge generates the appropriate PCI configuration access. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |