142 / 225 page ![]() Chapter 7 CAN Module (TXCAN) Preliminary 7-21 Bit Name Function Reset Value Mode 2 BO Bus Off status 1 = There is an abnormal rate of occurrences of errors on the CAN bus. This condition occurs when the transmit error counter TEC has reached the limit of 256. During “bus off”, no messages can be received or transmitted. The CAN module will go to “bus on” automatically after the “bus off recovery sequence”. After entering “bus off”, the error counters are undefined. 0 = Normal operation 0 R 1 EP Error Passive status 1 = The CAN module is in the error passive mode. 0 = The CAN module is in the error active mode. 0 R 0 EW Warning status 1 = At least one of the error counters has reached the warning level of 97. 0 = Both values of the error counters are less than 97. 0 R CAN Error Counter Register (CEC) Bit 15 8 7 0 Name TEC REC Bit Name Function Reset Value Mode 15:8 TEC Transmit error counter 0R 7:0 REC Receive error counter 0R The CAN module contains two error counters: receive error counter (REC) and transmit error counter (TEC). The values of both counters can be read via the MCU interface. These counters are incremented or decremented according to the CAN specification version 2.0B. A write access to the error counters is only possible in the test error mode (TSTERR bit in MCR is set). In this mode both the TEC and REC counters take over the value written to the lower byte of the register. The receive error counter is not increased after exceeding the error passive limit (128). After the correct reception of a message, the counter is set to a value between 119 and 127 (see CAN specification). After reaching the “bus off” status, the error counters are undefined. If the status “bus off” is reached, the receive error counter is incremented after 11 consecutive recessive bits on the bus. These 11 bits correspond to the gap between two telegrams on the bus. If the counter reaches the count 128, the module changes automatically to the status error active. All internal flags are reset and the error counters are deleted. The configuration registers keep the programmed values. The values of the error counters are undefined during “bus off” status. When TXCAN enters configuration mode (see paragraph “7.4.1 Configuration Mode”) the error counters will be cleared. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |