| Electronic Components Datasheet Search |
|
OR3TP12 Datasheet(PDF) 13 Page - Agere Systems |
|
|
|||||||||||||||||||||||||||||
OR3TP12 Datasheet(HTML) 13 Page - Agere Systems |
|
13 / 128 page ![]() Lucent Technologies Inc. 13 Data Sheet ORCA OR3TP12 FPSC March 2000 Embedded Master/Target PCI Interface Lucent Technologies Inc. PCI Bus Core Detailed Description The following sections describe the operation of the embedded PCI bus core interface. PCI Bus Commands The PCI bus core supports all commands required by the PCI Specification. The following table describes each command. Subsequent sections will describe the protocols in which the commands are used. Table 3. PCI Bus Command Descriptions Command Code (Binary) Command OR3TP12 Master Generates OR3TP12 Target Accepts Description 0000 Interrupt Acknowledge — — Only implemented by Master agents that interface to the system CPU and as Target by agents that incorporate the system interrupt controller. 0001 Special Cycle — — Target ignores, per PCI Specification Section 3.7.2. 0010 I/O Read √√ Target: Single accesses only, with bursts disconnected after first data phase. Delayed Mode (deltrn = 0): Terminates the initial access with a retry, recording internally the PCI address and byte enables for processing by the FPGA application. Subse- quent PCI accesses occurring before the FPGA application loads the Target read FIFO continues to result in retries. After the Target read FIFO is loaded by the FPGA applica- tion, the next read access that matches the stored parame- ters disconnects with the FPGA supplied data and the Target read logic is cleared. Nondelayed Mode (deltrn = 1, trburstpendn = 0): Accepted access inserts wait-states up to the initial latency count (16 or 32 clocks depending on the option selected in the FPSC configuration manager). During the wait-states, the FPGA application processes the read request and transfers data into the Target read FIFOs. If read data is transferred into the Target read FIFOs before the latency count expires, this read data is transferred to the PCI bus during initial request. If not, the PCI address, byte enables, and Target read data remain stored in the Target controller. The next access that matches the stored address and byte enables disconnects with the FPGA supplied data, and the Target read logic is cleared. Master: Single and burst operations are allowed. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |