| Electronic Components Datasheet Search |
|
PM7345 Datasheet(PDF) 114 Page - PMC-Sierra, Inc |
|
|
|||||||||||||||||||||||||||||
PM7345 Datasheet(HTML) 114 Page - PMC-Sierra, Inc |
|
114 / 306 page ![]() PM7345 S/UNI-PDH DATA SHEET PMC-931011 ISSUE 6 SATURN USER-NETWORK INTERFACE PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE 100 Register 19H: PMON Summed Excessive Zero Detect and Incoming Error Count MSB Bit Type Function Default Bit 7 R EXZS/IEC[15] X Bit 6 R EXZS/IEC[14] X Bit 5 R EXZS/IEC[13] X Bit 4 R EXZS/IEC[12] X Bit 3 R EXZS/IEC[11] X Bit 2 R EXZS/IEC[10] X Bit 1 R EXZS/IEC[9] X Bit 0 R EXZS/IEC[8] X EXZS/IEC[15:0]: In T3 mode, EXZS[15:0] represents the number of summed Excessive Zeros (EXZS) that occurred during the previous accumulation interval. One or more excessive zeros occurrences within an 85 bit DS3 information block is counted as one summed excessive zero. Excessive zeros are accumulated by this register only when the EXZSO and EXZDET are logic 1 in the DS3 FRMR Additional Configuration Register. This register accumulates summed line code violations when the EXZSO is logic 0. The count of summed line code violations is defined as the number of DS3 information blocks (85 bits) that contain one or more line code violations since the last time the summed LCV counter was polled. When the S/UNI-PDH is configured for E3 G.832 with Tandem Connection, these registers indicate the number of IEC errors encoded in the Network Operator byte that occurred during the previous accumulation interval. The IEC is encoded in binary. A binary value of 1111 for IEC is equivalent to 15 IECs, not 4 IECs. It is not envisioned that the Tandem Connection mode will be used in S/UNI-PDH applications. This counter is forced to zero when the S/UNI-PDH is configured for E3 G.751. The counter (and all other counters in the PMON) is polled by writing to any of the PMON or CPPM register addresses. Such a write transfers the internally accumulated count to the Summed Excessive Zeros Detect Registers and simultaneously resets the internal counter to begin a new cycle of error accumulation. This transfer and reset is carried out in a manner that coincident events are not lost. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |