154 / 306 page ![]() PM7345 S/UNI-PDH DATA SHEET PMC-931011 ISSUE 6 SATURN USER-NETWORK INTERFACE PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE 140 Register 39H: CPPM HCS Error Count MSB Bit Type Function Bit 7 Unused Bit 6 Unused Bit 5 Unused Bit 4 Unused Bit 3 R HCSE[11] Bit 2 R HCSE[10] Bit 1 R HCSE[9] Bit 0 R HCSE[8] HCSE[11:0]: HCSE[11:0] represents the number of header check sequence (HCS) errors that have been detected since the last time the HCSE error counter was polled. The counter (and all other counters in the CPPM) is polled by writing to any of the CPPM register addresses. Such a write transfers the internally accumulated count to the HCSE Error Count Registers and simultaneously resets the internal counter to begin a new cycle of error accumulation. This transfer occurs within 50 RCLK periods (1.2 µs for the DS3 bit rate; 1.45µs for the E3 bit rate) of the write. The transfer and reset is carried out in a manner that coincident events are not lost. HCS errors are not accumulated when the S/UNI-PDH has declared a PLCP loss of frame defect state (when the PLCP layer is enabled), or when the S/UNI-PDH has declared an out of cell delineation defect state (when direct cell delineation is enabled for non-PLCP based transmission formats) . The type of HCS error accumulated is determined by the HCSCNTSEL bit of S/UNI-PDH Data Link and FERF Control register. If HCSCNTSEL is a logic 1 and configured with HCS error correction disabled (HECEN=0 in register 53H), single bit errors are not counted when in HCS detection mode. If HCSCNTSEL is a logic 1 and configured with HCS error correction enabled (HECEN=1 in register 53H), single bit errors are counted in both correction mode and detection mode. If HCSCNTSEL is a logic 0, uncorrectable header errors are accumulated. These include single bit errors while the receive cell processor is in detection mode. The S/UNI-PDH transitions from the SYNC to the HUNT state on receipt of 7 consecutive cells with incorrect HCS values, and will indicate "Out of Cell Delineation" (RXCP Control Register 40H). However, the S/UNI-PDH does not correctly count the number of uncorrectable HCS errors received when the transition from SYNC to HUNT occurs. The uncorrectable HCS error count value |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |