Back Button AD9554 Datasheet HTML 27Page - Analog Devices AD9554 Datasheet HTML 28Page - Analog Devices AD9554 Datasheet HTML 29Page - Analog Devices AD9554 Datasheet HTML 30Page - Analog Devices AD9554 Datasheet HTML 31Page - Analog Devices AD9554 Datasheet HTML 32Page - Analog Devices AD9554 Datasheet HTML 33Page - Analog Devices AD9554 Datasheet HTML 34Page - Analog Devices AD9554 Datasheet HTML 35Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 31 / 116 page
background image
Data Sheet
AD9554
Rev. D | Page 31 of 116
Other reference input settings are in the following registers:
Reference input enable information is found in the DPLL
Feedback Dividers section.
Reference power-down information is found in
Register 0x0A01.
Reference switching mode settings are found in
Register 0x0A22 (DPLL_0), Register 0x0A42 (DPLL_1),
Register 0x0A62 (DPLL_2), and Register 0x0A82 (DPLL_3).
Digital PLL (DPLL) Controls and Settings
The DPLL control parameters are separate for DPLL_0 through
DPLL_3. They reside in the following registers:
Register 0x0400 to Register 0x041E (DPLL_0)
Register 0x0500 to Register 0x051E (DPLL_1)
Register 0x0600 to Register 0x061E (DPLL_2)
Register 0x0700 to Register 0x071E (DPLL_3)
These registers include the following settings:
30-bit free running frequency
DPLL pull-in range limits
DPLL closed-loop phase offset
Tuning word history control (for holdover operation)
Phase slew control (for controlling the phase slew rate
during a closed-loop phase adjustment)
Demapping control
With the exception of the free running tuning word, the default
values of these registers are fine for normal operation. The free
running frequency of the DPLL determines the frequency that
appears at the APLL input when user free run mode is selected.
The correct free running frequency is required for the APLL to
calibrate and lock correctly.
Output PLLs (APLLs) and Output Drivers
The registers that control the APLLs and output drivers reside
in the following registers:
Register 0x0430 to Register 0x043E (APLL_0)
Register 0x0530 to Register 0x053E (APLL_1)
Register 0x0630 to Register 0x063E (APLL_2)
Register 0x0730 to Register 0x073E (APLL_3)
The following functions are controlled in these registers:
APLL settings (feedback divider, charge pump current)
Output synchronization mode
Output divider values
Output enable/disable (disabled by default)
Output logic type
The APLL calibration and synchronization bits reside in the
following registers:
Register 0x0A20 (APLL_0)
Register 0x0A40 (APLL_1)
Register 0x0A60 (APLL_2)
Register 0x0A80 (APLL_3)
DPLL Feedback Dividers
Each DPLL has separate feedback divider settings for each
reference input, which allows the user to have each digital PLL
perform a different frequency translation. However, there is
only one reference divider (R divider) for each reference input.
The feedback divider register settings for DPLL_0 reside in the
following registers. Feedback divider registers for the remaining
three DPLLs mimic the structure of the DPLL_0 registers, but
are offsets by 0x0100 registers.
Register 0x0440 to Register 0x44C (DPLL_0 for REFA)
Register 0x044D to Register 0x459 (DPLL_0 for REFB)
Register 0x045A to Register 0x466 (DPLL_0 for REFC)
Register 0x0467 to Register 0x473 (DPLL_0 for REFD)
DPLL_1 for REFA to DPLL_1 for REFD: Same as DPLL_0
but offset by 0x0100 registers
DPLL_2 for REFA to DPLL_2 for REFD: Same as DPLL_0
but offset by 0x0200 registers
DPLL_3 for REFA to DPLL_3 for REFD: Same as DPLL_0
but offset by 0x0300 registers
These registers include the following settings:
Reference priority
Reference input enable (separate for each DPLL)
DPLL loop bandwidth
DPLL loop filter
DPLL feedback divider (integer portion)
DPLL feedback divider (fractional portion)
DPLL feedback divider (modulus portion)
Common Operational Controls
The common operational controls reside at Register 0x0A00 to
Register 0x0A14 and include the following:
Simultaneous calibration and synchronization of all PLLs
Global power-down
Reference power-down
Reference validation override
IRQ clearing (for all IRQs)



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com