Back Button AD9554 Datasheet HTML 30Page - Analog Devices AD9554 Datasheet HTML 31Page - Analog Devices AD9554 Datasheet HTML 32Page - Analog Devices AD9554 Datasheet HTML 33Page - Analog Devices AD9554 Datasheet HTML 34Page - Analog Devices AD9554 Datasheet HTML 35Page - Analog Devices AD9554 Datasheet HTML 36Page - Analog Devices AD9554 Datasheet HTML 37Page - Analog Devices AD9554 Datasheet HTML 38Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 34 / 116 page
background image
AD9554
Data Sheet
Rev. D | Page 34 of 116
The AD9554 also includes a demapping control function that
allows the user to adjust each of the AD9554 output frequencies
dynamically by periodically writing the actual level and desired
level of a first in, first out (FIFO). These levels are intended to
match the actual levels on the user system.
REFERENCE INPUT PHYSICAL CONNECTIONS
Four pairs of pins (REFA, REFA to REFD, REFD) provide
access to the reference clock receivers. To accommodate input
signals with slow rising and falling edges, both the differential
and single-ended input receivers employ hysteresis. Hysteresis
also ensures that a disconnected or floating input does not
cause the receiver to oscillate.
When configured for differential operation, the input receivers
accommodate either ac- or dc-coupled input signals. If the
input receiver is configured for dc-coupled LVDS mode, the
input receivers are capable of accepting dc-coupled LVDS
signals; however, only up to a maximum of 10.24 MHz. For
frequencies greater than that, ac-couple the input clock and use
ac-coupled differential mode. The receiver is internally dc
biased to handle ac-coupled operation; however, there is no
internal 50 Ω or 100 Ω termination.
When configured for single-ended operation, the input
receivers exhibit a pull-down load of 47 kΩ (typical). See
Register 0x0300 to Register 0x037E for the settings for the
reference inputs.
REFERENCE MONITORS
The accuracy of the input reference monitors depends on a
known and accurate system clock period. Therefore, the
function of the reference monitors is not operable until the
system clock is stable.
Reference Period Monitor
Each reference input has a dedicated monitor that repeatedly
measures the reference period. The AD9554 uses the reference
period measurements to determine the validity of the reference
based on a set of user provided parameters in the reference
input area of the register map. See Register 0x0304 through
Register 0x030E for the settings for Reference A, Register 0x0324
through Register 0x032E for the settings for Reference B,
Register 0x0344 through Register 0x034E for the settings for
Reference C, and Register 0x0364 through Register 0x036E for
the settings for Reference D.
The monitor compares the measured period of a particular
reference input with the parameters stored in the profile register
assigned to that same reference input. The parameters include
the reference period, an inner tolerance, and an outer tolerance.
A 40-bit number defines the reference period in units of
femtoseconds (fs). A 20-bit number defines the inner and outer
tolerances. The value stored in the register is the reciprocal of
the tolerance specification. For example, a tolerance specification
of 50 ppm yields a register value of 1/(50 ppm) = 1/0.000050 =
20,000 (0x04E20).
The use of two tolerance values provides hysteresis for the
monitor decision logic. The inner tolerance applies to a
previously faulted reference and specifies the largest period
tolerance that a previously faulted reference can exhibit before it
qualifies as unfaulted. The outer tolerance applies to an already
unfaulted reference. It specifies the largest period tolerance that
an unfaulted reference can exhibit before being faulted.
To produce decision hysteresis, the inner tolerance must be less
than the outer tolerance. That is, a faulted reference must meet
tighter requirements to become unfaulted than an unfaulted
reference must meet to become faulted.
Reference Validation Timer
Each reference input has a dedicated validation timer. The
validation timer establishes the amount of time that a previously
faulted reference must remain unfaulted before the AD9554
declares that it is valid. The timeout period of the validation
timer is programmable via a 16-bit register (Address 0x030F
and Address 0x0310 for Reference A). The 16-bit number stored in
the validation register represents units of milliseconds (ms),
which yields a maximum timeout period of 65,535 ms.
It is possible to disable the validation timer by programming the
validation timer to 0. With the validation timer disabled, the
user must validate a reference manually via the manual reference
validation override controls register (Register 0x0A02).
Reference Validation Override Control
The user can also override the reference validation logic and
either force an invalid reference to be treated as valid or force a
valid reference to be treated as an invalid reference. These
controls are in Register 0x0A02 to Register 0x0A03.
REFERENCE INPUT BLOCK
Unlike the AD9557, the AD9554 separates the DPLL reference
dividers from the feedback dividers.
The reference input block includes the input receiver, the reference
divider (R divider), and the reference input frequency monitor
for each reference input. The reference input settings for REFA
are grouped together in Register 0x0300 to Register 0x031E.
The corresponding registers for REFB through REFD are the
following: Register 0x320 to Register 0x33E, Register 0x340 to
Register 0x35E, and Register 0x0360 to Register 0x037E,
respectively.
These registers include the following settings:
Reference logic type (such as differential, single-ended)
Reference divider (20-bit R divider value)
Reference input period and tolerance
Reference validation timer
Phase and frequency lock detector settings
Phase step threshold



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com