| Electronic Components Datasheet Search |
|
AD9554 Datasheet(PDF) 35 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9554 Datasheet(HTML) 35 Page - Analog Devices |
|
35 / 116 page ![]() Data Sheet AD9554 Rev. D | Page 35 of 116 The reference prescaler reduces the frequency of this signal by an integer factor, R + 1, where R is the 20-bit value stored in the appropriate profile register and 0 ≤ R ≤ 1,048,575. Therefore, the frequency at the output of the R divider (or the input to the time-to-digital converter [TDC]) is as follows: 1 R f f R TDC After the R divider, the signal passes to a 4:4 crosspoint that allows any reference input signal to go to any DPLL. Each DPLL on the AD9554 has an independent set of feedback dividers for each reference input. A description of these settings can be found in the Digital PLL (DPLL) Core section. The AD9554 evaluation software includes a frequency planning wizard that configures the profile parameters based on the input and output frequencies. REFERENCE SWITCHOVER An attractive feature of the AD9554 is its versatile reference switchover capability. The flexibility of the reference switchover functionality resides in a sophisticated prioritization algorithm that is coupled with register-based controls. This scheme provides the user with maximum control over the state machine that handles the reference switchover. The main reference switchover control resides in the user mode registers in the PLL_0 through PLL_3 operational controls registers. The reference switching mode bits for each DPLL include the following: Register 0x0A22[4:2] for DPLL_0 Register 0x0A42[4:2] for DPLL_1 Register 0x0A62[4:2] for DPLL_2 Register 0x0A82[4:2] for DPLL_3 These bits allow the user to select one of the five operating modes of the reference switchover state machine that follows: Automatic revertive mode Automatic nonrevertive mode Manual with automatic fallback mode Manual with holdover fallback mode Full manual mode without holdover fallback In automatic modes, a fully automatic priority-based algorithm selects the active reference. When programmed for automatic mode, the device chooses the highest priority valid reference. When two or more references have the same priority, REFA has preference over REFB, and so on in alphabetical order. However, the reference position is used as a tiebreaker only and does not initiate a reference switch. An overview of the five operating modes follows: Automatic revertive mode. The device selects the highest priority valid reference and switches to a higher priority reference if it becomes available, even if the reference in use is still valid. In this mode, the user reference is ignored. Automatic nonrevertive mode. The device stays with the currently selected reference as long as it is valid, even if a higher priority reference becomes available. The user reference is ignored in this mode. Manual with automatic fallback mode. The device uses the user reference for as long as it is valid. If it becomes invalid, the reference input with the highest priority is chosen in accordance with the priority-based algorithm. Manual with holdover fallback mode. The user reference is the active reference until it becomes invalid. At that point, the device goes into holdover. Full manual mode without holdover fallback. The user reference is the active reference, regardless of whether it is valid. The user also can force the device directly into holdover or free run operation via the user holdover and user free run bits. In free run mode, the free run frequency tuning word registers define the free run output frequency. In holdover mode, the output frequency depends on the holdover control settings (see the Holdover section). Phase Build-Out Reference Switching The AD9554 supports phase build-out reference switching, which refers to a reference switchover that completely masks any phase difference between the previous reference and the new reference. That is, there is virtually no phase change detectable at the output when a phase build-out switchover occurs. DIGITAL PLL (DPLL) CORE DPLL Overview The AD9554 contains four separate DPLL cores (one each for DPLL_0 through DPLL_3), and each core operates independently of one another. A diagram of a single core is shown in Figure 27. Many of the blocks shown in this diagram are purely digital. DIGITAL LOOP FILTER ÷N0 24-BIT/24-BIT RESOLUTION FRAC0/ MOD0 18-BIT INTEGER TUNING WORD CLAMP AND HISTORY FREE RUN TW + SYSTEM CLOCK FROM APLL_0 TO APLL_0 R DIVIDER (20-BIT) REF INPUT MUX REF INPUT Figure 31. DPLL_0 Core |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |