Back Button PM7345 Datasheet HTML 155Page - PMC-Sierra, Inc PM7345 Datasheet HTML 156Page - PMC-Sierra, Inc PM7345 Datasheet HTML 157Page - PMC-Sierra, Inc PM7345 Datasheet HTML 158Page - PMC-Sierra, Inc PM7345 Datasheet HTML 159Page - PMC-Sierra, Inc PM7345 Datasheet HTML 160Page - PMC-Sierra, Inc PM7345 Datasheet HTML 161Page - PMC-Sierra, Inc PM7345 Datasheet HTML 162Page - PMC-Sierra, Inc PM7345 Datasheet HTML 163Page - PMC-Sierra, Inc Next Button
Zoom Inzoom in Zoom Outzoom out
 159 / 306 page
background image
PM7345 S/UNI-PDH
DATA SHEET
PMC-931011
ISSUE 6
SATURN USER-NETWORK INTERFACE
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
145
Register 3DH: CPPM Receive Cell Count MSB
Bit
Type
Function
Default
Bit 7
R
RCELL[15]
X
Bit 6
R
RCELL[14]
X
Bit 5
R
RCELL[13]
X
Bit 4
R
RCELL[12]
X
Bit 3
R
RCELL[11]
X
Bit 2
R
RCELL[10]
X
Bit 1
R
RCELL[9]
X
Bit 0
R
RCELL[8]
X
RCELL[15:0]:
RCELL[15:0] represents the aggregate number of cells that have been written to
the receive FIFO since the last time the receive cell counter was polled. Note
that this count represents the number of error-free, assigned cells that have been
received when idle/unassigned cell filtering and HCS error filtering are enabled.
The counter (and all other counters in the CPPM) is polled by writing to any of
the CPPM register addresses. Such a write transfers the internally accumulated
count to the Receive Cell Count Registers and simultaneously resets the internal
counter to begin a new cycle of error accumulation. This transfer occurs within
50 RCLK periods (1.2 µs for the DS3 bit rate; 1.45µs for the E3 bit rate) of the
write. The transfer and reset is carried out in a manner that coincident events are
not lost. Cells are not passed through the S/UNI-PDH when a PLCP loss of
frame defect state is declared (when the PLCP layer is enabled), or when an out
of cell delineation defect state is declared (when direct cell delineation is enabled
for non-PLCP based transmission formats) .



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com