Back Button PM7345 Datasheet HTML 158Page - PMC-Sierra, Inc PM7345 Datasheet HTML 159Page - PMC-Sierra, Inc PM7345 Datasheet HTML 160Page - PMC-Sierra, Inc PM7345 Datasheet HTML 161Page - PMC-Sierra, Inc PM7345 Datasheet HTML 162Page - PMC-Sierra, Inc PM7345 Datasheet HTML 163Page - PMC-Sierra, Inc PM7345 Datasheet HTML 164Page - PMC-Sierra, Inc PM7345 Datasheet HTML 165Page - PMC-Sierra, Inc PM7345 Datasheet HTML 166Page - PMC-Sierra, Inc Next Button
Zoom Inzoom in Zoom Outzoom out
 162 / 306 page
background image
PM7345 S/UNI-PDH
DATA SHEET
PMC-931011
ISSUE 6
SATURN USER-NETWORK INTERFACE
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA, INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
148
Register 40H: RXCP Control
Bit
Type
Function
Default
Bit 7
R/W
HCSPASS
0
Bit 6
R/W
HCSDQDB
0
Bit 5
R/W
HCSADD
0
Bit 4
R/W
HCK
0
Bit 3
R/W
BLOCK
0
Bit 2
R/W
DSCR
0
Bit 1
R
OOCDV
X
Bit 0
R/W
FIFORST
0
FIFORST:
The FIFORST bit is used to reset the receive FIFO. When a logic 1 is written to
FIFORST, the FIFO is immediately emptied, and incoming assigned cells are
ignored. When a logic 0 is written to FIFORST, the receive FIFO operates
normally.
OOCDV:
The OOCDV bit indicates the current out of cell delineation defect state. This bit
is valid when the ATM Cell Delineator (ATMF) Block is enabled. The ATMF block
is enabled (using the DELIN bit in the RXCP Framing Control Register) when
delineating cells in a non-PLCP based transmission format. When an HCS error
is detected in seven consecutive cells, OOCDV is set to logic 1. When six
consecutive cells containing no HCS errors are detected, OOCDV is set to logic
0.
DSCR:
The DSCR bit controls cell payload descrambling using the self-synchronizing
polynomial x43 + 1. Payload descrambling can be enabled for PLCP based and
non-PLCP based transmission systems. When a logic 1 is written to DSCR,
payload descrambling is enabled. When a logic 0 is written to DSCR, payload
descrambling is disabled.
BLOCK:
The BLOCK bit enables idle/unassigned and user-programmable cell filtering.
When a logic 1 is written to BLOCK, idle/unassigned cells or user-programmed
cells corresponding to the pattern specified in the Idle/Unassigned Cell Pattern
and User-programmable Cell Pattern Registers, and their associated Cell Mask
Registers, are blocked. When a logic 0 is written to BLOCK, only idle/unassigned
cells or user-programmed cells corresponding to the pattern specified in the



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com