Back Button SH7727 Datasheet HTML 163Page - Renesas Technology Corp SH7727 Datasheet HTML 164Page - Renesas Technology Corp SH7727 Datasheet HTML 165Page - Renesas Technology Corp SH7727 Datasheet HTML 166Page - Renesas Technology Corp SH7727 Datasheet HTML 167Page - Renesas Technology Corp SH7727 Datasheet HTML 168Page - Renesas Technology Corp SH7727 Datasheet HTML 169Page - Renesas Technology Corp SH7727 Datasheet HTML 170Page - Renesas Technology Corp SH7727 Datasheet HTML 171Page - Renesas Technology Corp Next Button
Zoom Inzoom in Zoom Outzoom out
 167 / 1109 page
background image
Section 2 CPU
Rev. 5.00 Dec 12, 2005 page 95 of 1034
REJ09B0254-0500
Conditional Operations and Data Transfer: Some instructions belonging to this class can be
executed conditionally, as described earlier. The specified condition is valid only for the B field of
the instruction, and is not valid for data transfer instructions for which a parallel specification is
made. Examples are shown in figure 2.17.
DCT PADD X0,Y0,A0
MOVX.W @R4+,X0
MOVY.W A0,@R6+R9 ;
When condition is True
Before execution:
After execution:
X0=H'33333333, Y0=H'55555555, A0=H'123456789A,
R4=H'00008000, R6=H'00008233, R9=H'00000004
(R4)=H'1111, (R6)=H'2222
X0=H'11110000, Y0=H'55555555, A0=H'0088888888,
R4=H'00008002, R6=H'00008237, R9=H'00000004
(R4)=H'1111, (R6)=H'3456
When condition is False
Before execution:
After execution:
X0=H'33333333, Y0=H'55555555, A0=H'123456789A,
R4=H'00008000, R6=H'00008233, R9=H'00000004
(R4)=H'1111, (R6)=H'2222
X0=H'11110000, Y0=H'55555555, A0=H'123456789A,
R4=H'00008002, R6=H'00008237, R9=H'00000004
(R4)=H'1111, (R6)=H'3456
Figure 2.17 Examples of Conditional Operations and Data Transfer Instructions
Assignment of NOPX and NOPY Instruction Codes: When there is no data transfer instruction
to be parallel-processed simultaneously with a DSP operation instruction, an NOPX or NOPY
instruction can be written as the data transfer instruction, or the instruction can be omitted. The
instruction code is the same whether an NOPX or NOPY instruction is written or the instruction is
omitted. Examples of NOPX and NOPY instruction codes are shown in table 2.34.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com