| Electronic Components Datasheet Search |
|
TUSB6250 Datasheet(PDF) 17 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
TUSB6250 Datasheet(HTML) 17 Page - Texas Instruments |
|
17 / 124 page ![]() Device Parameter Information 4−4 SLLS535A − January 2004 TUSB6250 Table 4−1. Controller Terminal Description (80-Pin TQFP) (Continued) TERMINAL I/O DESCRIPTION NAME NO. TYPE NOTES DESCRIPTION P3.7 24 I/O (2)(5) (9) 5-V fail-safe general-purpose I/O with internal configurable pullup and pulldown resistors. This terminal can be used as a GPIO or DASP function, which is implemented by the end product developer’s custom firmware. After a power-on reset, this terminal defaults as input with the internal pullup resistor activated. The MCU can reconfigure the pullup and pulldown resistors, if desired. RST_ATA 61 O (2)(9) ATA/ATAPI: Asynchronous drive-reset signal. This terminal should be connected to the corresponding pin of the ATA/ATAPI interface connector on the end product PCB. OTHER GPIOS (GENERAL PURPOSE I/Os) P2.7 3 I/O (1)(6) (8) General-purpose I/O with an internal controllable pullup resistor. After a power-on reset, this terminal defaults as an input with an internal pullup resistor activated. The MCU can disable the pullup resistor if desired. P2.6, P2.5, P2.4, P2.0 62, 64, 65, 74 I/O (2)(5) (9) 5-V fail-safe general-purpose I/O with internal configurable pullup and pulldown resistors. After power-on reset, these terminals default as inputs with the internal pullup resistor activated. The MCU can reconfigure the pullup and pulldown resistors if desired. P2.3 67 O (3) General-purpose open-drain output without internal pullup and pulldown resistors. P2.2/ PWR500 68 O (3) General-purpose open-drain output. This terminal can be controlled by the firmware to inform the ATA/ATAPI device connected to the TUSB6250 that the end product device (including the TUSB6250 itself) is allowed to draw 500 mA from the USB bus after the device is fully enumerated and configured as a USB bus-powered device. P2.1/ PWR100 69 O (3) General-purpose open-drain output. During the USB enumeration phase, This terminal is asserted by the boot code to inform the ATA/ATAPI device connected to the TUSB6250 that the end product device (including the TUSB6250 itself) is allowed to draw 100 mA from the USB bus. After the boot code relinquishes control to the firmware when USB enumeration, configuration, and firmware download are finished, the firmware can reconfigure the function of this terminal for other usage, as long as such usage is not conflicting with the previous usage, which, for example, can be implemented in the end product for power sequencing control purposes. It should be noted that, for self-powered applications, if VBUS from the USB bus is not present (for example, the USB cable is not connected) during boot time, the boot code does not assert this terminal. In this condition, it is the firmware’s responsibility to assert this terminal, once the firmware is downloaded and gains control. P3.5, P3.4 70, 71 I/O (2)(5) (9) 5-V fail-safe general-purpose I/O with internal configurable pullup and pulldown resistors. After power-on reset, these terminals default as inputs with an internal pullup resistor activated. The MCU can reconfigure the pullup and pulldown resistors if desired. These two terminals can be used as remote wake-up event inputs. The end product developer’s custom firmware can utilize these two terminals to implement some end product specific functions, such as cartridge insertion detection, eject button pressed, or external control input to request the end product custom firmware to put the TUSB6250’s ATA/ATAPI bus into 3-state. P3.3/CD2, P3.2/CD1 72 73 I/O (2)(5) (9) 5-V fail-safe general-purpose I/O with internal configurable pullup and pulldown resistors. After power-on reset, these terminals default as inputs with an internal pullup resistor activated. The MCU can reconfigure the pullup and pulldown resistors, if desired. These terminals can be used as GPIOs or compact flash card insertion/removal detection function implemented by the end product developer’s custom firmware. These terminals are remote wake-up capable inputs, if enabled. NOTES: 1. 3-state 3.3-V LVCMOS output ( ±8-mA drive/sink). 2. 3-state 3.3-V LVCMOS output, 5-V fail-safe ( ±8-mA drive/sink). The 5-V fail-safe means this output buffer can be exposed to a 5-V application environment. Although it can not output 5 V when interfacing with the 5-V ATA/ATAPI device, an external pullup resistor to a 5-V power source can be used to pull the output voltage up to 5 V. The fail-safe buffer is designed to be protected from damage under a condition where the buffer is exposed to 5 V, while the device is powered down (its supply voltage is zero). 3. Open-drain output (8-mA sink), 5-V fail-safe, without internal pullup and pulldown resistors. 4. 3.3-V LVCMOS hysteresis input. 5. TTL-compatible, 5-V fail-safe, hysteresis input. 6. 3.3-V LVCMOS input without hysteresis. 7. Open-drain output (4-mA sink) with an internal pullup resistor. 8. Internal 100- µA active pullup resistor. 9. Configurable internal 200- µA active pullup and pulldown resistors. 10. Controllable internal 200- µA active pulldown resistor 11. 1.8-V LVCMOS input buffer 12. 1.8-V LVCMOS output buffer |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |