| Electronic Components Datasheet Search |
|
AD9166 Datasheet(PDF) 31 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9166 Datasheet(HTML) 31 Page - Analog Devices |
|
31 / 138 page ![]() Data Sheet AD9166 Rev. 0 | Page 31 of 138 PHYSICAL LAYER The physical layer of the JESD204B interface, hereafter referred to as the deserializer, has eight identical channels. Each channel consists of the terminators, an equalizer, a clock and data recovery (CDR) circuit, and the 1:40 demux function (see Figure 49). EQUALIZER CDR 1:40 DESERIALIZER FROM SERDES PLL SPI CONTROL TERMINATION SERDINx± Figure 49. Deserializer Block Diagram JESD204B data is input to the AD9166 via the SERDINx± 1.2 V differential input pins as per the JESD204B specification. Interface Power-Up and Input Termination Before using the JESD204B interface, it must be powered up by setting Register 0x200, Bit 0 = 0. In addition, each physical lane (PHY) that is not being used (SERDINx±) must be powered down. To do so, set the corresponding Bit x for Physical Lane x in Register 0x201 as follows: Set the bit to 0 when the physical lane is used. Set the bit to 1 when the physical lane is not used. The AD9166 autocalibrates the input termination to 50 Ω. Before running the termination calibration, Register 0x2A7 and Register 0x2AE must be written as described in Table 17 to guarantee proper calibration. The termination calibration begins when Register 0x2A7, Bit 0 and Register 0x2AE, Bit 0 transition from low to high. Register 0x2A7 controls autocalibration for PHY 0, PHY 1, PHY 6, and PHY 7. Register 0x2AE controls autocalibration for PHY 2, PHY 3, PHY 4, and PHY 5. The PHY x termination autocalibration routine is listed in Table 17. Table 17. PHYx Termination Autocalibration Routine Address Value Description 0x2A7 0x01 Autocalibrate PHY 0, PHY 1, PHY 6, and PHY 7 terminations 0x2AE 0x01 Autocalibrate PHY 2, PHY 3, PHY 4, and PHY 5 terminations The input termination voltage of the DAC is sourced externally through the DAC_1P2_SER pins. It is recommended that the JESD204B inputs be ac-coupled to the JESD204B transmit device using 100 nF capacitors. The calibration code of the termination can be read from Bits[3:0] in Register 0x2AC (PHY 0, PHY 1, PHY 6, and PHY 7) and Register 0x2B3 (PHY 2, PHY 3, PHY 4, and PHY 5). If needed, the termination values can be adjusted or set using several registers. To override the autocalibrated termination values, use the TERM_BLKx_CTRLREG1 registers (Register 0x2A8 and Register 0x2AF). Set the registers as follows: Default setting: set to 0xXXX0XXXX. The termination block autocalibrates the termination values. Overwrite setting: set to 0xXXX1XXXX to overwrite the autocalibration with the termination values in Bits[3:1] of Register 0x2A8 and Register 0x2AF. Individual offsets from the autocalibration value for each lane are programmed in Bits[3:0] of Register 0x2BB to Register 0x2C2. The value is a signed magnitude, with Bit 3 as the sign bit. The total range of the termination resistor value is about 94 Ω to 120 Ω, with approximately 3.5% increments across the range (for example, smaller steps at the bottom of the range than at the top). Receiver Eye Mask The AD9166 complies with the JESD204B specification regarding the receiver eye mask and is capable of capturing data that complies with this mask. Figure 50 shows the receiver eye mask normalized to the data rate interval with a 600 mV VTT swing. See the JESD204B specification for more information regarding the eye mask and permitted receiver eye opening. 525 55 0 –55 –525 0 0.5 1.00 0.35 0.65 TIME (UI) LV-OIF-11G-SR RECEIVER EYE MASK Figure 50. Receiver Eye Mask for 600 mV VTT Swing Clock Relationships The following clock rates are used throughout the remainder of the JESD204B Serial Data Interface section. The relationship between any of the clocks can be derived from the following equations: DataRate = (DACRate)/(InterpolationFactor) LaneRate = (20 × DataRate × M)/L ByteRate = LaneRate/10 where: M is the JESD204B parameter for converters per link. L is the JESD204B parameter for lanes per link. This relationship comes from 8-bit/10-bit encoding, where each byte is represented by 10 bits. PCLK Rate = ByteRate/4 The processing clock is used for a quad-byte decoder. FrameRate = ByteRate/F where F is JESD204B parameter for octets per frame per lane. PCLK Factor = FrameRate/PCLK Rate = 4/F |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |