| Electronic Components Datasheet Search |
|
AD9166 Datasheet(PDF) 37 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
AD9166 Datasheet(HTML) 37 Page - Analog Devices |
|
37 / 138 page ![]() Data Sheet AD9166 Rev. 0 | Page 37 of 138 Sync Processing Modes Overview The AD9166 supports several LMFC sync processing modes. These modes are one shot, continuous, and monitor modes. All sync processing modes perform a phase check to confirm that the LMFC is phase aligned to an alignment edge. In Subclass 1, the SYSREF± signal acts as the alignment edge. In Subclass 0, an internal processing clock (PCLK) acts as the alignment edge. The sync modes are described in the following sections (One-Shot Sync Mode (SYNC_MODE = Register 0x03A, Bits[1:0] = 0b10), Continuous Sync Mode (SYNC_MODE = Register 0x03A, Bits[1:0] = 0b01), Monitor Sync Mode (SYNC_MODE = Register 0x03A, Bits[1:0]) = 0b00), and Sync Procedure). See the Sync Procedure section for details on the procedure for syncing the LMFC signals. One-Shot Sync Mode (SYNC_MODE = Register 0x03A, Bits[1:0] = 0b10) In one-shot sync mode, a phase check occurs on only the first alignment edge that is received after the sync machine is armed. After the phase is aligned on the first edge, the AD9166 transitions to monitor mode. Though an LMFC synchronization occurs only once, the SYSREF± signal can still be continuous. In this case, the phase is monitored and reported, but no clock phase adjustment occurs. Continuous Sync Mode (SYNC_MODE = Register 0x03A, Bits[1:0] = 0b01) Continuous sync mode must be used in Subclass 1 only with a periodic SYSREF± signal. In continuous sync mode, a phase check/alignment occurs on every alignment edge. Continuous sync mode differs from one-shot sync mode in two ways. First, no SPI cycle is required to arm the device. The alignment edge seen after continuous sync mode is enabled results in a phase check. Second, a phase check occurs on every alignment edge in continuous sync mode. Monitor Sync Mode (SYNC_MODE = Register 0x03A, Bits[1:0]) = 0b00) Monitor sync mode allows the user to monitor the phase error in real time. Use this sync mode with a periodic SYSREF± signal. The phase is monitored and reported, but no clock phase adjustment occurs. When an alignment request (SYSREF± edge) occurs, snapshots of the last phase error are placed into readable registers for reference (Register 0x037 and Register 0x038, Bits[3:0]), and, if appropriate, the IRQ_SYSREF_JITTER interrupt is set. Sync Procedure The procedure for enabling the sync is as follows: 1. Set up the DAC; the SERDES PLL locks it and enables the CDR (see the Start-Up Sequence section). 2. Set Register 0x039 (SYSREF± jitter window). A minimum of four fCLK cycles is recommended. See Table 22 for settings. 3. Optionally, read back the SYSREF± count to check whether the SYSREF± pulses are being received. a. Set Register 0x036 = 0. Writing anything to SYSREF_COUNT resets the count. b. Set Register 0x034 = 0. Writing anything to SYNC_LMFC_STAT0 saves the data for readback and registers the count. c. Read SYSREF_COUNT from the value from Register 0x036. 4. Perform a one-shot sync. a. Set Register 0x03A = 0x00. Clear one shot mode if already enabled. b. Set Register 0x03A = 0x02. Enable one-shot sync mode. The state machine enters monitor mode after a sync occurs. 5. Optionally, read back the SYNC_LMFC_STATx registers to verify that the synchronization completed correctly. a. Set Register 0x034 = 0. Register 0x034 must be written to read the value. b. Read Register 0x035 and Register 0x034 to find the value of SYNC_LMFC_STATx. It is recommended to set SYNC_LMFC_STATx to 0 but it can be set to 4, or a LMFC period in fCLK − 4, due to jitter. 6. Optionally, read back the SYSREF_PHASEx registers to identify which phase of the divide by 4 was used to sample SYSREF±. Read Register 0x038 and Register 0x037 as thermometer code. The MSBs of Register 0x037, Bits[7:4] normally show the thermometer code value. 7. Turn the link on (Register 0x300, Bit 0 = 1). 8. Read back Register 0x302 (dynamic link latency). 9. Repeat reestablishment of the link several times (Step 1 to Step 7) and note the dynamic link latency values. Based on the noted values, program the LMFC delay (Register 0x304) and the LMFC variable (Register 0x306), and then restart the link. Table 21. Sync Processing Modes Sync Processing Mode SYNC_MODE (Register 0x03A, Bits[1:0]) No synchronization 0b00 One shot 0b10 Continuous 0b01 Table 22. SYSREF± Jitter Window Tolerance SYSREF± Jitter Window Tolerance (fCLK Cycles) SYSREF_JITTER_WINDOW (Register 0x039, Bits[5:0])1 ±½ 0x00 ±4 0x04 ±8 0x08 ±12 0x0C ±16 0x10 ±20 0x14 ±24 0x18 ±28 0x1C 1 The two least significant digits are ignored because the SYSREF± signal is sampled with a divide by 4 version of fCLK. As a result, the jitter window is set by the fCLK ÷ 4 clock rather than fCLK. It is recommended that at least a four- device clock SYSREF± jitter window be chosen. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |