Back Button AD9166 Datasheet HTML 52Page - Analog Devices AD9166 Datasheet HTML 53Page - Analog Devices AD9166 Datasheet HTML 54Page - Analog Devices AD9166 Datasheet HTML 55Page - Analog Devices AD9166 Datasheet HTML 56Page - Analog Devices AD9166 Datasheet HTML 57Page - Analog Devices AD9166 Datasheet HTML 58Page - Analog Devices AD9166 Datasheet HTML 59Page - Analog Devices AD9166 Datasheet HTML 60Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 56 / 138 page
background image
AD9166
Data Sheet
Rev. 0 | Page 56 of 138
The TX_ENABLE pin can be used for more accurate timing
when enabling or disabling the DAC output. The effect of the
TX_ENABLE pin can be configured by the TX_ENABLE
register (Register 0x03F) as is used for the SPI controlled func-
tions, and the pin can be configured to have the same effects as
the SPI controlled function, namely to zero the input to the
digital datapath or to zero the output from the digital datapath.
In addition, the TX_ENABLE pin can also be configured to
ramp down (or up) the full-scale current of the DAC. The ramp
down reduces the output power of the DAC by about 20 dB
from full scale to the minimum output current.
The TX_ENABLE pin can also be programmed to reset the
NCO phase accumulator. See Table 38 for a description of the
settings available for the TX_ENABLE register function.
Table 38. TX_ENABLE Settings
Register 0x03F
Setting
Description
Bit 7
0
SPI control: zero data to the DAC
1
SPI control: allow data to pass to
the DAC
Bit 6
0
SPI control: zero data at input to
the datapath
1
SPI control: allow data to enter the
datapath
Bits[5:4]
N/A1
Reserved
Bit 3
0
Use SPI writes to reset the NCO2
1
Use TX_ENABLE to reset the NCO
Bit 2
0
Use SPI control to zero data to the
DAC
1
Use TX_ENABLE pin to zero data to
the DAC
Bit 1
0
Use SPI control to zero data at the
input to the datapath
1
Use TX_ENABLE pin to zero data at
input to the datapath
Bit 0
0
Use SPI registers to control the full-
scale current
1
Use TX_ENABLE pin to control the
full-scale current
1 N/A means not applicable.
2. Use SPI writes to reset the NCO if resetting the NCO is desired. Register
0x800, Bits[7:6] determine whether the NCO is reset. See Table 37 for more
details.
DATAPATH PRBS
The datapath PRBS can verify the AD9166 datapath receives
and correctly decodes data. The datapath PRBS verifies the
JESD204B parameters of the transmitter and receiver match, the
lanes of the receiver are mapped appropriately, the lanes are
appropriately inverted, and, if necessary, the start-up routine is
correctly implemented.
To run the datapath PRBS test, complete the following steps:
1.
Set up the device in the desired operating mode using the
start-up sequence.
2.
Send PRBS7 or PRBS15 data.
3.
Write Register 0x14B. Bit 2 = 0 for PRBS7 or Bit 2 = 1 for
PRBS15.
4.
Write Register 0x14B, Bits[1:0] = 0b11 to enable and reset
the PRBS test.
5.
Write Register 0x14B, Bits[1:0] = 0b01 to enable the PRBS
test and release reset.
6.
Wait 500 ms.
7.
Check the status of the PRBS by checking the IRQ for the I
and Q path PRBS as described in the Datapath PRBS IRQ
section.
8.
Read Register 0x14B, Bits[7:6]. Bit 6 is 0 if the I channel
has any errors. Bit 7 is 0 if the Q channel has any errors.
9.
Read Register 0x14C to read the error count for the I channel.
10. Read Register 0x14D to read the error count for the Q
channel. The PRBS processes 32 bits at a time, and compares
the 32 new bits to the previous set of 32 bits. The PRBS
detects and reports only one error in every group of 32 bits.
Therefore, the error count partly depends on when the
errors are seen.
For example, see the following sequences:
Bits: 32 good; 31 good, 1 bad; 32 good (one error)
Bits: 32 good; 22 good, 10 bad; 32 good (one error)
Bits: 32 good; 31 good, 1 bad; 31 good, 1 bad; 32 good (two
errors)
DATAPATH PRBS IRQ
The PRBS fail signals for the I and Q path are available as IRQ
events. Use Register 0x020, Bits[1:0] to enable the fail signals,
and then use Register 0x024, Bits[1:0] to read back the status
and reset the IRQ signals. See the Interrupt Request Operation
section for more information.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com