Back Button AD9166 Datasheet HTML 31Page - Analog Devices AD9166 Datasheet HTML 32Page - Analog Devices AD9166 Datasheet HTML 33Page - Analog Devices AD9166 Datasheet HTML 34Page - Analog Devices AD9166 Datasheet HTML 35Page - Analog Devices AD9166 Datasheet HTML 36Page - Analog Devices AD9166 Datasheet HTML 37Page - Analog Devices AD9166 Datasheet HTML 38Page - Analog Devices AD9166 Datasheet HTML 39Page - Analog Devices Next Button
Zoom Inzoom in Zoom Outzoom out
 35 / 138 page
background image
Data Sheet
AD9166
Rev. 0 | Page 35 of 138
JESD204B Serial Link Establishment
A brief summary of the high speed serial link establishment
process for Subclass 1 is provided. See Section 5.3.3 of the
JESD204B specifications document for complete details.
Step 1: Code Group Synchronization
Each receiver must locate /K/ (K28.5) characters in its input bit
stream. After four consecutive /K/ characters are detected on all
link lanes, the receiver block deasserts the SYNCOUT± signal
to the transmitter block at the receiver LMFC edge.
The transmitter captures the change in the SYNCOUT± signal
and, at a future transmitter LMFC rising edge, starts the ILAS.
Step 2: Initial Lane Alignment Sequence
The main purposes of this phase are to align all the lanes of the
link and to verify the parameters of the link.
Before the link is established, write each of the link parameters
to the receiver device to designate how data is sent to the
receiver block.
The ILAS consists of four or more multiframes. The last character
of each multiframe is a multiframe alignment character, /A/.
The first, third, and fourth multiframes are populated with
predetermined data values. Note that Section 8.2 of the JESD204B
specifications document describes the data ramp that is expected
during ILAS. The AD9166 does not require this ramp. The
deframer uses the final /A/ of each lane to align the ends of the
multiframes within the receiver. The second multiframe contains
an /R/ (K.28.0), /Q/ (K.28.4), and then data corresponding to the
link parameters. Additional multiframes can be added to the
ILAS if needed by the receiver. By default, the AD9166 uses four
multiframes in the ILAS (this can be changed in Register 0x478). If
using Subclass 1, exactly four multiframes must be used.
After the last /A/ character of the last ILAS, multiframe data
begins streaming. The receiver adjusts the position of the /A/
character such that it aligns with the internal LMFC of the
receiver at this point.
Step 3: Data Streaming
In this phase, data is streamed from the transmitter block to the
receiver block. Optionally, data can be scrambled. Scrambling
does not start until the very first octet following the ILAS.
The receiver block processes and monitors the data it receives
for errors, including the following:
Bad running disparity (8-bit/10-bit error)
Not in table (8-bit/10-bit error)
Unexpected control character
Bad ILAS
Interlane skew error (through character replacement)
If any of these errors exist, they are reported back to the
transmitter in one of the following ways (see the JESD204B
Error Monitoring section for details):
SYNCOUT± signal assertion: resynchronization
(SYNCOUT± signal pulled low) is requested at each error
for the last two errors. For the first three errors, an optional
resynchronization request can be asserted when the error
counter reaches a set error threshold.
For the first three errors, each multiframe with an error in
it causes a small pulse on SYNCOUT±.
Errors can optionally trigger an interrupt request (IRQ)
event, which can be sent to the transmitter.
For more information about the various test modes for
verifying the link integrity, see the JESD204B Test Modes
section.
Lane First In/First Out (FIFO)
The FIFOs in front of the crossbar switch and deframer synchro-
nize the samples sent on the high speed serial data interface
with the deframer clock by adjusting the phase of the incoming
data. The FIFO absorbs timing variations between the data source
and the deframer to allow up to two PCLK cycles of drift from
the transmitter. The FIFO_STATUS_REG_0 register and FIFO_
STATUS_REG_1 register (Register 0x30C and Register 0x30D,
respectively) can be monitored to identify whether the FIFOs
are full or empty.
Lane FIFO Interrupt Request (IRQ)
An aggregate lane FIFO overflow/underflow error bit is also
available as an IRQ event. Use Register 0x020, Bit 2 to enable
the FIFO overflow/underflow error bit, and then use
Register 0x024, Bit 2 to read back its status and reset the IRQ
signal. See the Interrupt Request Operation section for more
information.
Crossbar Switch
Register 0x308 to Register 0x30B allow arbitrary mapping of
physical lanes (SERDINx±) to logical lanes used by the SERDES
deframers.
Table 20. Crossbar Registers
Address
Bits
Logical Lane
0x308
[2:0]
SRC_LANE0
0x308
[5:3]
SRC_LANE1
0x309
[2:0]
SRC_LANE2
0x309
[5:3]
SRC_LANE3
0x30A
[2:0]
SRC_LANE4
0x30A
[5:3]
SRC_LANE5
0x30B
[2:0]
SRC_LANE6
0x30B
[5:3]
SRC_LANE7
Write each SRC_LANEx with the number (x) of the desired
physical lane (SERDINx±) from which to obtain data. By
default, all logical lanes use the corresponding physical lane as
their data source. For example, by default, SRC_LANE0 = 0.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com