302 / 307 page ![]() RELEASED S/UNI-622-MAX PMC-Sierra, Inc. PM5356 S/UNI-622-MAX DATASHEET PMC-1980589 ISSUE 6 SATURN USER NETWORK INTERFACE (622-MAX) PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA INC., AND FOR ITS CUSTOMERS’ INTERNAL USE 292 18.7 JTAG Test Port Timing Table 25: JTAG Port Interface (Figure 46) Symbol Description Min Max Units TCK Frequency 4 MHz TCK Duty Cycle 40 60 % tSTMS TMS Set-up time to TCK 25 ns tHTMS TMS Hold time to TCK 25 ns tSTDI TDI Set-up time to TCK 25 ns tHTDI TDI Hold time to TCK 25 ns tPTDO TCK Low to TDO Valid 2 50 ns tVTRSTB TRSTB Pulse Width 100 ns Figure 46: JTAG Port Interface Timing tVtrstb tVtrstb tPtdo tHtms tStms tHtdi tStdi TCK TDI TMS TDO TRSTB Notes on Input Timing: 1. When a set-up time is specified between an input and a clock, the set-up time is the time in nanoseconds from the 1.4 Volt point of the input to the 1.4 Volt point of the clock. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|