| Electronic Components Datasheet Search |
|
PM5356 Datasheet(PDF) 255 Page - PMC-Sierra, Inc |
|
|
|||||||||||||||||||||||||||||
PM5356 Datasheet(HTML) 255 Page - PMC-Sierra, Inc |
|
255 / 307 page ![]() RELEASED S/UNI-622-MAX PMC-Sierra, Inc. PM5356 S/UNI-622-MAX DATASHEET PMC-1980589 ISSUE 6 SATURN USER NETWORK INTERFACE (622-MAX) PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA INC., AND FOR ITS CUSTOMERS’ INTERNAL USE 245 Notes: 1. SONET requires Z0 bytes to be set to the number corresponding to the STS-1 column number. SDH considers those bytes reserved. 2. When forcing a constant Z0 pattern (SDH_J0/ZO is high), the Z0 bytes must be DC balanced (approximately the same number of ones and zeros) as the bytes are not scrambled. Failure to do so may cause downstream clock recovery to lose lock. 3. SONET uses 64 byte trace messages while SDH uses 16 byte trace messages. 4. SDH specification requires the detector of SS bits to be “10”. 5. The SS bits are undefined for SONET, but must be set to “10” for SDH. 13.4 Bit Error Rate Monitor The S/UN-622-MAX provides two BERM blocks. One can be dedicated to monitor at the Signal Degrade (SD) error rate and the other dedicated to monitor at the Signal Fail (SF) error rate. The Bit Error Rate Monitor (BERM) block counts and monitors line BIP errors over programmable periods of time (window size). It can monitor to declare an alarm or to clear it if the alarm is already set. A different threshold and accumulation period must be used to declare or clear the alarm, whether or not those two operations are not performed at the same BER. The following table lists the recommended content of the BERM registers for different error rates (BER). Both BERMs in the TSB are equivalent and are programmed similarly. In a normal application they will be set to monitor different BER. When the SF/SD CMODE bit is set to one, the clearing monitoring is recommended to be performed using a window size that is 8 times longer than the declaration window size. When the SF/SD CMODE bit is set to zero, the clearing monitoring is recommended to be performed using a window size equal to the declaration window size. In all cases the clearing threshold is calculated for a BER that is 10 times lower than the declaration BER, as required in the references. The table indicates the declare BER and evaluation period only. The saturation threshold is not listed in the table, and should be programmed with the value 0xFFF by default, deactivating saturation. Saturation capabilities are provided to allow the user to address issues associated with error bursts. For additional information, please refer to the BERM application note (PMC- 950820) for more detailed information. |
|
Link URL |
| Does ALLDATASHEET help your business so far? [ DONATE ] |
About Alldatasheet | Advertisement | Contact us | Privacy Policy | Link to Datasheet | Link Exchange | Manufacturer List All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |