Back Button PM5356 Datasheet HTML 251Page - PMC-Sierra, Inc PM5356 Datasheet HTML 252Page - PMC-Sierra, Inc PM5356 Datasheet HTML 253Page - PMC-Sierra, Inc PM5356 Datasheet HTML 254Page - PMC-Sierra, Inc PM5356 Datasheet HTML 255Page - PMC-Sierra, Inc PM5356 Datasheet HTML 256Page - PMC-Sierra, Inc PM5356 Datasheet HTML 257Page - PMC-Sierra, Inc PM5356 Datasheet HTML 258Page - PMC-Sierra, Inc PM5356 Datasheet HTML 259Page - PMC-Sierra, Inc Next Button
Zoom Inzoom in Zoom Outzoom out
 255 / 307 page
background image
RELEASED
S/UNI-622-MAX
PMC-Sierra, Inc.
PM5356
S/UNI-622-MAX
DATASHEET
PMC-1980589
ISSUE 6
SATURN USER NETWORK INTERFACE (622-MAX)
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
245
Notes:
1. SONET requires Z0 bytes to be set to the number corresponding to the STS-1
column number. SDH considers those bytes reserved.
2. When forcing a constant Z0 pattern (SDH_J0/ZO is high), the Z0 bytes must be DC
balanced (approximately the same number of ones and zeros) as the bytes are not
scrambled. Failure to do so may cause downstream clock recovery to lose lock.
3. SONET uses 64 byte trace messages while SDH uses 16 byte trace messages.
4. SDH specification requires the detector of SS bits to be “10”.
5. The SS bits are undefined for SONET, but must be set to “10” for SDH.
13.4 Bit Error Rate Monitor
The S/UN-622-MAX provides two BERM blocks. One can be dedicated to
monitor at the Signal Degrade (SD) error rate and the other dedicated to monitor
at the Signal Fail (SF) error rate.
The Bit Error Rate Monitor (BERM) block counts and monitors line BIP errors
over programmable periods of time (window size). It can monitor to declare an
alarm or to clear it if the alarm is already set. A different threshold and
accumulation period must be used to declare or clear the alarm, whether or not
those two operations are not performed at the same BER. The following table
lists the recommended content of the BERM registers for different error rates
(BER). Both BERMs in the TSB are equivalent and are programmed similarly. In
a normal application they will be set to monitor different BER.
When the SF/SD CMODE bit is set to one, the clearing monitoring is
recommended to be performed using a window size that is 8 times longer than
the declaration window size. When the SF/SD CMODE bit is set to zero, the
clearing monitoring is recommended to be performed using a window size equal
to the declaration window size. In all cases the clearing threshold is calculated
for a BER that is 10 times lower than the declaration BER, as required in the
references. The table indicates the declare BER and evaluation period only.
The saturation threshold is not listed in the table, and should be programmed
with the value 0xFFF by default, deactivating saturation. Saturation capabilities
are provided to allow the user to address issues associated with error bursts.
For additional information, please refer to the BERM application note (PMC-
950820) for more detailed information.



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com