Back Button PM5356 Datasheet HTML 252Page - PMC-Sierra, Inc PM5356 Datasheet HTML 253Page - PMC-Sierra, Inc PM5356 Datasheet HTML 254Page - PMC-Sierra, Inc PM5356 Datasheet HTML 255Page - PMC-Sierra, Inc PM5356 Datasheet HTML 256Page - PMC-Sierra, Inc PM5356 Datasheet HTML 257Page - PMC-Sierra, Inc PM5356 Datasheet HTML 258Page - PMC-Sierra, Inc PM5356 Datasheet HTML 259Page - PMC-Sierra, Inc PM5356 Datasheet HTML 260Page - PMC-Sierra, Inc Next Button
Zoom Inzoom in Zoom Outzoom out
 256 / 307 page
background image
RELEASED
S/UNI-622-MAX
PMC-Sierra, Inc.
PM5356
S/UNI-622-MAX
DATASHEET
PMC-1980589
ISSUE 6
SATURN USER NETWORK INTERFACE (622-MAX)
PROPRIETARY AND CONFIDENTIAL TO PMC-SIERRA INC., AND FOR ITS CUSTOMERS’ INTERNAL USE
246
Table 9: Recommended BERM settings
STS
Declare
BER
Evals /
Second
SF/SD
SMODE
SF/SD
CMODE
SF/SD
SAP
SF/SD
DTH
SF/SD
CTH
STS-12c
10-3
0.008
0
0
0x000008
0x956
0x1E9
STS-12c
10-4
0.008
0
0
0x000008
0x1A5
0x03D
STS-12c
10-5
0.025
0
1
0x000019
0x084
0x08E
STS-12c
10-6
0.250
0
1
0x0000FA
0x085
0x08E
STS-12c
10-7
2.500
0
1
0x0009C4
0x085
0x08E
STS-12c
10-8
21.000
0
1
0x005208
0x06E
0x079
STS-12c
10-9
167.000
0
1
0x028C58
0x056
0x062
STS-3c
10-3
0.008
0
0
0x000008
0x245
0x083
STS-3c
10-4
0.013
0
1
0x00000D
0x0A3
0x0B4
STS-3c
10-5
0.100
0
1
0x000064
0x084
0x08E
STS-3c
10-6
1.000
0
1
0x0003E8
0x085
0x08E
STS-3c
10-7
10.000
0
1
0x002710
0x085
0x08E
STS-3c
10-8
83.000
0
1
0x014438
0x06D
0x077
STS-3c
10-9
667.000
0
1
0x0A2D78
0x055
0x061
13.5 Auto Alarm Control Configuration
The S/UNI-622-MAX supports the automatic generation of transmit alarm
information based on the detected receive alarms. This functionality is controlled
by the master AUTOxx register bits in register 0x02 and the Auto Path and Line
Configuration registers 0x08 to 0x0F.
When consequential action is enabled for a given alarm condition, other S/UNI-
622-MAX configuration registers become important. For instance, if
consequential action for signal degrade is enabled, the RASE must be configured
for the desired alarm thresholds. The following table lists register settings for
path RDI and extended path RDI interfaces.
Table 10: Path RDI and Extended RDI Register Settings
Register
RDI
EPRDI
0x09
11111100
01101100
0x0A
xxxxxx00
11111100



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100  ...More


Datasheet Download

Go To PDF Page


Link URL



Does ALLDATASHEET help your business so far?  [ DONATE ] 

About Alldatasheet   |   Advertisement   |   Contact us   |   Privacy Policy   |   Link to Datasheet    |   Link Exchange   |   Manufacturer List
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com